Liebe Nutzerinnen und Nutzer in der Zeit von Montag 22.04. 9:00Uhr bis voraussichtlich Mitwoch 24.04. 9:00Uhr ist JLUpub aufgrund von Wartungsarbeiten nicht erreichbar. Danke für Ihr Verständnis. Dear users, JLUpub will be unavailable from Monday 22.04. 9:00 a.m. until probably Wednesday 24.04. 9:00 a.m. due to maintenance work. Thank you for your understanding.

Zur Kurzanzeige

dc.contributor.authorGroß, Alexandra
dc.date.accessioned2023-03-16T20:20:52Z
dc.date.available2021-04-27T10:30:56Z
dc.date.available2023-03-16T20:20:52Z
dc.date.issued2020
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:hebis:26-opus-160339
dc.identifier.urihttps://jlupub.ub.uni-giessen.de//handle/jlupub/15556
dc.identifier.urihttp://dx.doi.org/10.22029/jlupub-14938
dc.description.abstractDie Rekonstruktion knöcherner Defekte bei Revisionseingriffen von Endoprothesen mit dem femoralen Impaktierungsverfahren bietet die Möglichkeit, eine langfristige knöcherne Integration mit guten klinischen Ergebnissen zu gewährleisten. Allogener, nativer kryokonservierter Knochen kommt häufig für dieses Verfahren zur Anwendung.Diese Studie untersucht die Auswirkungen der Thermodesinfektion auf das Impaktionsverhalten von Knochenchips verschiedener Geometrie mit anschließender Einzementierung im Vergleich zu nativ belassenen Knochen.Aus zuvor thermodesinfizierten bzw. nativ belassenen porcinen Femurköpfen wurden Knochenchips verschiedener Größe hergestellt. Gemäß erarbeiteter Befüllungsmethoden wurden Partikel unterschiedlicher Größe innerhalb eines Zylindermodells mit standardisierter Krafteinwirkung impaktiert. Die optimale Dichteverteilung wurde durch computertomographische Messungen des Feststoff-, Luft-, Wasser- und Fettanteils untersucht. Die für die jeweilige Behandlung beste Partikelkombination wurde daraufhin genutzt, um die im CT dargestellte Zementverteilung und Knochenkontaktfläche zu analysieren. Als statistische Methoden kamen Varianzanalysen mit Bonferroni-Korrektur sowie der LSD Post-Hoc-Test zur Anwendung. Der alpha-Fehler wurde mit 5% angegeben.Impaktierter nativer Knochen zeigt weniger Lufteinschlüsse, resultierend in einer insgesamt besseren Feststoffdichteverteilung. Im Vergleich weist die ausgewählte Methode zur Impaktierung des prozessierten Knochens mit tendenziell größeren Partikeln jedoch segmental vergleichbare Werte auf. In der zweiten Versuchsreihe stellen sich das Zementvolumen, die -penetrationsflächen sowie die Zement-Transplantat-Kontaktfläche für das native Spongiosa-Kompakta-Gemisch als insgesamt signifikant größer dar; auch die Zementverteilung ist nach distal signifikant weiterreichend.Thermodesinfektion scheint somit das Deformationsverhalten der Chips zu beeinflussen. Veränderte Kohäsionseigenschaften nach der Thermodesinfektion sind im Vergleich zum nativen Knochen zu vermuten und könnten eine abweichende Zementverteilung erklären. Thermodesinfizierter Knochen ist geeignet, eine adäquate Impaktionsdichte vergleichbar der des nativen Materials zu erreichen. Weitere Untersuchungen zur Optimierung des Kohäsionsverhaltens mit Auswirkung auf die Zementpenetration erscheinen sinnvoll.de_DE
dc.description.abstractThe reconstruction of bony defects during endoprosthesis revision surgery using impaction bone grafting offers the possibility of longstanding osseous integration with good clinical results. Native allogeneic, cryopreserved bone is often used for the procedure.This study investigates the influence of thermodisinfection on the impaction behavior of bone chips of different geometry with subsequent cementation compared to native bone.Bone chips of various sizes were made from previously thermodisinfected or untreated porcine femoral heads. According to the developed loading methods, particles of different sizes were impacted in a cylinder model with standardized force application. The optimal density distribution was investigated by computer tomographic measurements of the solid, air, water and fat content. The best particle combination for the respective treatment was subsequently used to analyze the cement distribution and bone contact area shown in the CT. The statistical methods used were variance analysis with Bonferroni correction and the LSD post-hoc-test. The error probability was set at alpha = 5%.Impacted native bone shows less inclusion of air resulting in an overall better distribution of density. However, the selected method for processed bone impaction with tendentially larger particles shows segmentally comparable results. In the second test series, the cement volume, the penetration area and the cement graft contact area for the native cancellous bone and compacta mixture are significantly higher; in the distal shaft area, the cement distribution is also significantly wider.Thermodisinfection thus seems to influence the deformation behaviour of the chips. Changed cohesion properties after thermodisinfection are to be assumed in comparison to native bone and could explain a different cement distribution. Thermodisinfected bone is suitable for achieving an adequate impaction density comparable to that of native material. Further investigations to optimize the cohesion behaviour with an effect on the cement penetration seem to be useful.en
dc.language.isode_DEde_DE
dc.rightsIn Copyright*
dc.rights.urihttp://rightsstatements.org/page/InC/1.0/*
dc.subjectImpaction-Bone-Graftingde_DE
dc.subjectThermodesinfektionde_DE
dc.subjectKnochenersatzverfahrende_DE
dc.subjectimpaction-bone-graftingen
dc.subjectthermodesinfectionen
dc.subject.ddcddc:610de_DE
dc.titleEntwicklung und Validierung eines Impaktierungsverfahrens als Vergleichsstudie zwischen nativ belassenen und thermodesinfizierten Knochenchips zur Verbesserung der Stabilität und Integration von Endoprothesen in der umliegenden Knochenmatrixde_DE
dc.title.alternativeDevelopment and validation of an impact procedure as a comparative study between natively left and thermo-desinfected bone chips to improve the stability and integration of endoprostheses in the surrounding bone matrixen
dc.typedoctoralThesisde_DE
dcterms.dateAccepted2021-02-25
local.affiliationFB 11 - Medizinde_DE
thesis.levelthesis.doctoralde_DE
local.opus.id16033
local.opus.instituteKlinik und Poliklinik für Orthopädie und Orthopädische Chirurgie; Labor für Biomechanikde_DE
local.opus.fachgebietMedizinde_DE