Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats

Thumbnail
Files in this item
10.1177_10406387221083621.pdf (1.251Mb)
Date
2022
Author
Zelmer, Kim-Lina Charlotte
Bauer, Natali
Moritz, Andreas
Metadata
Show full item record
BibTeX Export
Quotable link
http://dx.doi.org/10.22029/jlupub-15637
Abstract

A novel laser- and impedance-based point-of-care hematology analyzer (POCA), the vCell 5 (scil Animal Care), providing a complete blood count with 5-part leukocyte differential count has recently been introduced to veterinary laboratories. We evaluated the analyzer for use in dogs and cats including method comparison and assessment of linearity, ... carryover, and precision. Fresh blood samples from 192 healthy and diseased dogs and 159 cats were analyzed, and results were compared to reference methods (i.e., microhematocrit [PCV], Advia 2120 hematology analyzer). Total observed error (TEo) was calculated from CV, obtained at 3 concentrations, and bias%, and compared to total allowable error (TEa). For both species, excellent correlation (rs = 0.93–0.99) was seen between methods for WBC and RBC, hematocrit, hemoglobin, and platelet counts (PLT), except for feline PLT (rs = 0.79). Quality requirements (TEo < TEa) were fulfilled for WBC (TEo = 8.6–11.1%; TEa = 20%) and RBC (TEo = 3.5–7%; TEa = 10%), hematocrit (TEo = 5.7–9.4%; TEa = 10%), PCV (cat TEo = 7.8%; TEa = 10%), mean corpuscular volume (cat TEo = 5.1%; TEa = 7%), and PLT (TEo = 13.1–24.1%; TEa = 25%). Excellent linearity was demonstrated for WBC, RBC, and PLT, and hemoglobin. CVs of <2% for WBC, RBC, hematocrit, hemoglobin, and of <5% (dog) and 8% (cat) for PLT were demonstrated for values within the RI. Except for calculated variables and well-known species-specific deviations in feline PLT, scil POCA results were correlated favorably with reference method results and complied with quality requirements for cats and dogs.

Original publication in

Journal of veterinary diagnostic investigation 34, 3 (2022), 504-517

URI of original publication
https://doi.org/10.1177/10406387221083621
Collections
  • Publikationen im Open Access gefördert durch die UB
Namensnennung - Nicht kommerziell 4.0 International
Namensnennung - Nicht kommerziell 4.0 International

Contact Us | Impressum | Privacy Policy | OAI-PMH
 

 

Browse

All of JLUpubCommunities & CollectionsOrganisational UnitDDC-ClassificationPublication TypeAuthorsBy Issue DateThis CollectionOrganisational UnitDDC-ClassificationPublication TypeAuthorsBy Issue Date

My Account

LoginRegister

Statistics

View Usage Statistics

Contact Us | Impressum | Privacy Policy | OAI-PMH