Intra-pulp temperature increase of equine cheek teeth during treatment with motorized grinding systems : influence of grinding head position and rotational speed

Thumbnail
Dateien zu dieser Ressource
10.1186_1746_6148_10_47.pdf (1.110Mb)
Datum
2014
Autor
Haeussler, Silvia
Luepke, Matthias
Seifert, Hermann
Staszyk, Carsten
Metadaten
Zur Langanzeige
BibTeX Export
Zitierlink
http://dx.doi.org/10.22029/jlupub-8444
Zusammenfassung

BACKGROUND: In equine practice, teeth corrections by means of motorized grinding systems are standard procedure. The heat resulting from that treatment may cause irreparable damage to the dental pulp. It has been shown that a 5.5degreesC temperature rise may cause severe destruction in pulp cells. Hence, the capability to continuously form ... secondary dentine is lost, and may lead, due to equine-typical occlusal tooth abrasion, to an opening of the pulp cavity.To obtain reliable data on the intra-pulp increase in temperature during corrective treatments, equine cheek teeth (CT) were modified in a way (occlusal surface smoothed, apical parts detached, pulp horns standardized) that had been qualified in own former published studies. All parameters influencing the grinding process were standardized (force applied, initial temperatures, dimensions of pulp horns, positioning of grinding disk, rotational speed). During grinding experiments, imitating real dental treatments, the time span for an intra-pulp temperature increase of 5.5degreesC was determined. RESULTS: The minimum time recorded for an intra-pulp temperature increase of 5.5degreesC was 38s in mandibular CT (buccal grinding, 12,000rpm) and 70s in maxillary CT (flat occlusal grinding, 12,000rpm). The data obtained showed that doubling the rotational speed of the disk results in halving the time span after which the critical intra-pulp temperature increase in maxillary CT is reached. For mandibular CT, the time span even drops by two thirds. CONCLUSION: The use of standardized hypsodont CT enabled comparative studies of intra-pulp heating during the grinding of occlusal tooth surfaces using different tools and techniques. The anatomical structure of the natural vital hypsodont tooth must be kept in mind, so that the findings of this study do not create a deceptive sense of security with regard to the time-dependent heating of the native pulp.

URI der Erstpublikation
https://doi.org/10.1186/1746-6148-10-47
Sammlungen
  • Publikationen im Open Access gefördert durch die UB
Namensnennung 3.0 International
Namensnennung 3.0 International

Kontakt | Impressum | Datenschutzerklärung | OAI-PMH
 

 

Stöbern

Gesamter BestandBereiche & SammlungenOrganisationseinheitDDC-KlassifikationPublikationstypAutorErscheinungsjahrDiese SammlungOrganisationseinheitDDC-KlassifikationPublikationstypAutorErscheinungsjahr

Mein Benutzerkonto

EinloggenRegistrieren

Statistik

Benutzungsstatistik

Kontakt | Impressum | Datenschutzerklärung | OAI-PMH