A comparative clinical study on the transfer accuracy of conventional and digital implant impressions using a new reference key-based method
dc.contributor.author | Schmidt, Alexander | |
dc.contributor.author | Rein, Peter Engelbert | |
dc.contributor.author | Wöstmann, Bernd | |
dc.contributor.author | Schlenz, Maximiliane Amelie | |
dc.date.accessioned | 2022-11-23T16:08:38Z | |
dc.date.available | 2022-11-23T16:08:38Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | https://jlupub.ub.uni-giessen.de//handle/jlupub/9723 | |
dc.identifier.uri | http://dx.doi.org/10.22029/jlupub-9111 | |
dc.language.iso | en | |
dc.rights | Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject.ddc | ddc:610 | |
dc.title | A comparative clinical study on the transfer accuracy of conventional and digital implant impressions using a new reference key-based method | |
dc.type | article | |
local.affiliation | FB 11 - Medizin | |
local.source.epage | 469 | |
local.source.journaltitle | Clinical oral implants research | |
local.source.spage | 460 | |
local.source.uri | https://doi.org/10.1111/clr.13715 | |
local.source.volume | 32 |