The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid–based in vitro study

dc.contributor.authorSchlenz, Maximiliane Amelie
dc.contributor.authorKlaus, Katharina
dc.contributor.authorSchmidt, Alexander
dc.contributor.authorWöstmann, Bernd
dc.contributor.authorMersmann, Marco
dc.contributor.authorRuf, Sabine
dc.contributor.authorBock, Niko Christian
dc.date.accessioned2023-11-15T13:37:08Z
dc.date.available2023-11-15T13:37:08Z
dc.date.issued2022
dc.description.abstractObjectives: The aim of this in vitro study was to investigate the influence of fixed orthodontic appliances (FOAs) on the transfer accuracy of full-arch impressions by five intraoral scanners (IOSs): CS3600, Primescan, Trios 4, Medit i500, Emerald S, and one conventional alginate impression (CAI). Materials and methods: To compare the data with the actual model situation, an established reference aid–based method was applied. A test model with human teeth was used and modified for each testing group, resulting in five different settings: natural teeth (group A), metal brackets without/with wire (groups B/C), ceramic brackets without/with wire (groups D/E). A total of 300 (n = 12 × 5 × 5) scan datasets of IOSs were analyzed using a 3D software (GOM Inspect) and 60 (n = 12 × 5) plaster casts of CAI were measured with a coordinate measurement machine. The deviations between the reference aid and the impressions were determined. Results: For all groups with brackets (B to E), IOSs showed a higher transfer accuracy compared to CAI, even for long-span distances. However, some significant differences between the IOSs were observed (p < 0.05). Conclusions: Within the limitations of this in vitro study, IOSs can be recommended for impressions with and without FOAs, even if CAI showed the smallest average deviations in settings without FOAs. Clinical relevance: IOSs are widely used in orthodontics and the current study demonstrated that their use enables fast impression taking even in settings with fixed orthodontic appliances. In addition, for these settings, the transfer accuracy is higher than with conventional alginate impressions. Nevertheless, a re-investigation in a clinical setting should be performed to verify the current in vitro findings.
dc.identifier.urihttps://jlupub.ub.uni-giessen.de//handle/jlupub/18654
dc.identifier.urihttp://dx.doi.org/10.22029/jlupub-18018
dc.language.isoen
dc.rightsNamensnennung 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectIntraoral scanner
dc.subjectDigital dentistry
dc.subjectAccuracy
dc.subjectPrecision
dc.subjectTrueness
dc.subjectFull-arch impression
dc.subjectFixed orthodontic appliance
dc.subject.ddcddc:610
dc.titleThe transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid–based in vitro study
dc.typearticle
local.affiliationFB 11 - Medizin
local.source.epage283
local.source.journaltitleClinical oral investigations
local.source.spage273
local.source.urihttps://doi.org/10.1007/s00784-022-04721-5
local.source.volume27

Dateien

Originalbündel
Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
10.1007_s00784-022-04721-5.pdf
Größe:
2.24 MB
Format:
Adobe Portable Document Format