Profiling intact steroid sulfates and unconjugated steroids in biological fluids by liquid chromatography-tandem mass spectrometry (LC-MS-MS)

dc.contributor.authorGaluska, Christina E.
dc.contributor.authorHartmann, Michaela F.
dc.contributor.authorSánchez-Guijo, Alberto
dc.contributor.authorBakhaus, Katharina
dc.contributor.authorGeyer, Joachim
dc.contributor.authorSchuler, Gerhard
dc.contributor.authorZimmer, Klaus-Peter
dc.contributor.authorWudy, Stefan A.
dc.date.accessioned2023-06-02T13:37:37Z
dc.date.available2020-05-20T08:30:31Z
dc.date.available2023-06-02T13:37:37Z
dc.date.issued2013
dc.description.abstractWithin the combined DFG research project "Sulfated Steroids in Reproduction" an analytical method was needed for determining sulfated and unconjugated steroids with highest specificity out of different biological matrices such as aqueous solution, cell lysate and serum. With regard to this analytical challenge, LC-MS-MS presents the technique of choice because it permits (1) analysis of the intact steroid conjugate, (2) allows for simultaneous determination of multiple analytes (profiling, targeted metabolomics approach) and (3) is independent of phenomena such as cross-reactivity. Sample work up consisted of incubation of sample with internal standards (deuterium labeled steroids) followed by solid phase extraction. Only serum samples required a protein precipitation step prior to solid phase extraction. The extract was divided in two parts: six steroid sulfates (E1S, E2S, AS, 16-OH-DHEAS, PREGS, DHEAS) were analyzed by C18aQ-ESI-MS-MS in negative ion mode and eleven unconjugated steroids (E3, 16-OH-DHEA, E1, E2, (4)A, DHEA, T, 17-OH-PREG, Prog, An, PREG) were analyzed by C18-APCI-MS-MS in positive ion mode. For steroid sulfates, we found high sensitivities with LoQ values ranging from 0.08 to 1 ng mL(-1). Unconjugated steroids showed LoQ values between 0.5 and 10 ng mL(-1). Calibration plots showed excellent linearity. Mean intra- and inter-assay CVs were 2.4% for steroid sulfates and 6.4% for unconjugated steroids. Accuracy - determined in a two-level spike experiment - showed mean relative errors of 5.9% for steroid sulfates and 6.1% for unconjugated steroids. In summary, we describe a novel LC-MS-MS procedure capable of profiling six steroid sulfates and eleven unconjugated steroids from various biological matrices.en
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:hebis:26-opus-151344
dc.identifier.urihttps://jlupub.ub.uni-giessen.de//handle/jlupub/16366
dc.identifier.urihttp://dx.doi.org/10.22029/jlupub-15746
dc.language.isoende_DE
dc.rightsIn Copyright*
dc.rights.urihttp://rightsstatements.org/page/InC/1.0/*
dc.subject.ddcddc:610de_DE
dc.titleProfiling intact steroid sulfates and unconjugated steroids in biological fluids by liquid chromatography-tandem mass spectrometry (LC-MS-MS)en
dc.typearticlede_DE
local.affiliationFB 11 - Medizinde_DE
local.commentDieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich. This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.
local.opus.fachgebietMedizinde_DE
local.opus.id15134
local.opus.instituteSteroid Research & Mass Spectrometry Unit, Division of Pediatric Endocrinology & Diabetlogyde_DE
local.source.freetextAnalyst, 138, 3792-3801, doi: 10.1039/c3an36817cde_DE