Serum proteome profiling identifies novel and powerful markers of cystic fibrosis liver disease

dc.contributor.authorRath, Timo
dc.contributor.authorHage, Lisa
dc.contributor.authorKügler, Marion
dc.contributor.authorMenendez Menendez, Katrin
dc.contributor.authorZachoval, Reinhart
dc.contributor.authorNaehrlich, Lutz
dc.contributor.authorSchulz, Richard
dc.contributor.authorRoderfeld, Martin
dc.contributor.authorRoeb, Elke
dc.date.accessioned2022-11-18T09:50:18Z
dc.date.available2013-08-16T05:37:14Z
dc.date.available2022-11-18T09:50:18Z
dc.date.issued2013
dc.description.abstractBackground and Aims Cystic Fibrosis associated liver disease (CFLD) develops in approximately 30% of CF patients. However, routine sensitive diagnostic tools for CFLD are lacking. Within this study, we aimed to identify new experimental biomarkers for the detection of CFLD. Methods 45 CF patients were included in the study and received transient elastography. Differential regulation of 220 different serum proteins was assessed in a subgroup of patients with and without CFLD. Most interesting candidate proteins were further quantified and validated by ELISA in the whole patient cohort. To assess a potential relation of biomarker expression to the degree of hepatic fibrosis, serum biomarkers were further determined in 18 HCV patients where liver histology was available. Results 43 serum proteins differed at least 2-fold in patients with CFLD compared to those without liver disease as identified in proteome profiling. In ELISA quantifications, TIMP-4 and Endoglin were significantly up-regulated in patients with CFLD as diagnosed by clinical guidelines or increased liver stiffness. Pentraxin-3 was significantly decreased in patients with CFLD. Serum TIMP-4 and Endoglin showed highest values in HCV patients with liver cirrhosis compared to those with fibrosis but without cirrhosis. At a cut-off value of 6.3 kPa, transient elastography compassed a very high diagnostic accuracy and specificity for the detection of CFLD. Among the biomarkers, TIMP-4 and Endoglin exhibited a high diagnostic accuracy for CFLD. Diagnostic sensitivities and negative predictive values were increased when elastography and TIMP-4 and Endoglin were combined for the detection of CFLD. Conclusions Serum TIMP-4 and Endoglin are increased in CFLD and their expression correlates with hepatic staging. Determination of TIMP-4 and Endoglin together with transient elastography can increase the sensitivity for the non-invasive diagnosis of CFLD.en
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:hebis:26-opus-100277
dc.identifier.urihttps://jlupub.ub.uni-giessen.de//handle/jlupub/8998
dc.identifier.urihttp://dx.doi.org/10.22029/jlupub-8386
dc.language.isoende_DE
dc.rightsNamensnennung 3.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/*
dc.subject.ddcddc:610de_DE
dc.titleSerum proteome profiling identifies novel and powerful markers of cystic fibrosis liver diseaseen
dc.typearticlede_DE
local.affiliationFB 11 - Medizinde_DE
local.opus.fachgebietMedizinde_DE
local.opus.id10027
local.source.freetextPLoS ONE 8(3):e58955de_DE
local.source.urihttps://doi.org/10.1371/journal.pone.0058955

Dateien

Originalbündel
Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
journal.pone.0058955.pdf
Größe:
2.42 MB
Format:
Adobe Portable Document Format