Evaluation of a novel moving threshold gating strategy for assessment of reticulated platelets in dogs using the ADVIA 2120 analyzer
dc.contributor.author | Kuhn, Anja | |
dc.contributor.author | Weiler, Kristina | |
dc.contributor.author | Gibbs, Graham | |
dc.contributor.author | Prechtl, Gottfried | |
dc.contributor.author | Bauer, Natali | |
dc.contributor.author | Moritz, Andreas | |
dc.date.accessioned | 2023-12-07T09:10:28Z | |
dc.date.available | 2023-12-07T09:10:28Z | |
dc.date.issued | 2023 | |
dc.description.abstract | Background: A novel method using a moving threshold (r-PLTmt) to determine canine r-PLTs (reticulated platelets) has been introduced for ADVIA 2120 software v6.11.7. Objectives: We aimed to evaluate absolute (ar-PLTmt) and percent (%r-PLTmt) prior to and after visual inspection of scattergrams (ar-PLTmtv, %rPLTmtv) compared with flow cytometry (flow) and to determine reference intervals (RIs) in 120 dogs. Methods: For method comparison, 42 blood samples of healthy and thrombocytopenic dogs were included. Calculation of Spearman's rho, Bland–Altman, and Passing-Bablok analysis was performed. Coefficients of variation (CVs) were determined for three concentration levels. Results: Moderate correlations between %r-PLTmt and %r-PLTmtv (rs 0.75–0.76) were seen compared with flow cytometry. The CV for medium %r-PLTs counts assessed with flow cytometry was 12.9%. Comparable CVs were obtained for ar-PLTmt (14.4%) and %r-PLTmt (15.7%), and ar-PLTmtv and %r-PLTmtv (10.9% and 12.9%, respectively). At low and high concentration levels, CVs for % and absolute r-PLTmt/rPLTmtv ranged between 23%–30% and 15%–20%. In patients with microcytic hypochromic erythrocytes, CVs for ar-PLTmt and %r-PLTmt were 36%–66%. Visual inspection of scattergrams resulted in a marked decrease in CV ranging between 15% and 20%. A proportional bias of 10.8% between %r-PLTmt and flow cytometry became lower (9.7%) after visual validation of scattergrams. Passing-Bablok analysis showed proportional and constant error. RIs for r-PLTmt and r-PLTmtv were 0.2%–3.8% and 0.6–10.2 × 109/L and 0.3%–4.5% and 1.1–10.3 × 109/L, respectively. Median values for %r-PLTmtv were higher in young adults (≤2 years) than in older dogs (P = 0.03). Conclusions: r-PLTmt and r-PLTmtv were moderately correlated with flow cytometry. Visual inspection of scattergrams is recommended. | |
dc.identifier.uri | https://jlupub.ub.uni-giessen.de//handle/jlupub/18771 | |
dc.identifier.uri | http://dx.doi.org/10.22029/jlupub-18135 | |
dc.language.iso | en | |
dc.rights | Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject.ddc | ddc:630 | |
dc.title | Evaluation of a novel moving threshold gating strategy for assessment of reticulated platelets in dogs using the ADVIA 2120 analyzer | |
dc.type | article | |
local.affiliation | FB 10 - Veterinärmedizin | |
local.source.epage | 21 | |
local.source.journaltitle | Veterinary clinical pathology | |
local.source.spage | 11 | |
local.source.uri | https://doi.org/10.1111/vcp.13168 | |
local.source.volume | 52 |
Dateien
Originalbündel
1 - 1 von 1
Lade...
- Name:
- 10.1111_vcp.13168.pdf
- Größe:
- 2.44 MB
- Format:
- Adobe Portable Document Format
- Beschreibung: