• Policy
    • FAQ JLUdocs
    • FAQ JLUdata
    • Publishing in JLUdocs
    • Publishing in JLUdata
    • Publishing Contract
    • English
    • Deutsch
View Item 
  •   JLUpub Home
  • JLUdocs
  • Publikationen im Open Access gefördert durch die UB
  • View Item
  •   JLUpub Home
  • JLUdocs
  • Publikationen im Open Access gefördert durch die UB
  • View Item
  • Info
    • Policy
    • FAQ JLUdocs
    • FAQ JLUdata
    • Publishing in JLUdocs
    • Publishing in JLUdata
    • Publishing Contract
  • English 
    • English
    • Deutsch
  • Login
JavaScript is disabled for your browser. Some features of this site may not work without it.

Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol

Thumbnail
Files in this item
10.3390_ma12223802.pdf (2.134Mb)
Date
2019-11-19
Author
Streckbein, Philipp
Meier, Mathias
Kähling, Christopher
Wilbrand, Jan-Falco
Langguth, Tobias
Schaaf, Heidrun
Howaldt, Hans-Peter
Streckbein, Roland
Attia, Sameh
Metadata
Show full item record
BibTeX Export
Quotable link
http://dx.doi.org/10.22029/jlupub-472
Abstract

Precise fitting and immobilisation of bone transplants at the recipient site is of utmost importance for the healing process. With the help of the standardised Osseo Transfer System, the recipient site is adjusted to the graft, rather than vice versa as it is typically done. The aim of this study was to analyse donor-site morbidity after ... harvesting cylindrical bone grafts from the retromolar region using the Osseo Transfer System. The patient satisfaction with the surgical procedures was also evaluated. All patients treated with this standardised reconstruction method between 2006 and 2013 at the Department of Cranio-Maxillofacial Surgery, University Hospital Giessen, were included in this study. Complications were recorded and evaluated. Bone graft success and patient satisfaction were documented with a questionnaire, and then confirmed by clinical and radiological follow-up examinations. Fifty-four patients were treated and 64 harvested cylindrical autologous bone grafts were transplanted. In all cases, dental implants could be inserted after bone healing. One patient lost an implant, associated with failure of the bone graft. Six patients who were examined continued to show neurological disorders in locally limited areas. No complete or long-term damage of the inferior alveolar nerve occurred. More than 94% (n = 52) of the patients were 'very satisfied' or 'satisfied' with the results and would recommend this surgical treatment to other patients. The standardised Osseo Transfer was an effective treatment option for small and mid-sized alveolar ridge augmentations. A low donor-site morbidity rate and a high transplant success rate were verified. The Osseo Transfer System demonstrated to be a reliable surgical technique without major complications. We highly recommend this surgical augmentation procedure as a surgical treatment for local bone defects.

Original publication in

Materials 12, 22 (2019-11-19), 3802

URI of original publication
https://doi.org/10.3390/ma12223802
Collections
  • Publikationen im Open Access gefördert durch die UB
Attribution 4.0 International
Attribution 4.0 International

Contact Us | Impressum | Privacy Policy | OAI-PMH
 

 

Browse

All of JLUpubCommunities & CollectionsOrganisational UnitDDC-ClassificationPublication TypeAuthorsBy Issue DateThis CollectionOrganisational UnitDDC-ClassificationPublication TypeAuthorsBy Issue Date

My Account

LoginRegister

Statistics

View Usage Statistics

Contact Us | Impressum | Privacy Policy | OAI-PMH