• Leitlinien
    • FAQ JLUdocs
    • FAQ JLUdata
    • Publizieren in JLUdocs
    • Publizieren in JLUdata
    • Veröffentlichungsvertrag
    • English
    • Deutsch
Dokumentanzeige 
  •   JLUpub Startseite
  • JLUdocs
  • Publikationen im Open Access gefördert durch die UB
  • Dokumentanzeige
  •   JLUpub Startseite
  • JLUdocs
  • Publikationen im Open Access gefördert durch die UB
  • Dokumentanzeige
  • Info
    • Leitlinien
    • FAQ JLUdocs
    • FAQ JLUdata
    • Publizieren in JLUdocs
    • Publizieren in JLUdata
    • Veröffentlichungsvertrag
  • Deutsch 
    • English
    • Deutsch
  • Einloggen
JavaScript is disabled for your browser. Some features of this site may not work without it.

Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol

Thumbnail
Dateien zu dieser Ressource
10.3390_ma12223802.pdf (2.134Mb)
Datum
2019-11-19
Autor
Streckbein, Philipp
Meier, Mathias
Kähling, Christopher
Wilbrand, Jan-Falco
Langguth, Tobias
Schaaf, Heidrun
Howaldt, Hans-Peter
Streckbein, Roland
Attia, Sameh
Metadaten
Zur Langanzeige
BibTeX Export
Zitierlink
http://dx.doi.org/10.22029/jlupub-472
Zusammenfassung

Precise fitting and immobilisation of bone transplants at the recipient site is of utmost importance for the healing process. With the help of the standardised Osseo Transfer System, the recipient site is adjusted to the graft, rather than vice versa as it is typically done. The aim of this study was to analyse donor-site morbidity after ... harvesting cylindrical bone grafts from the retromolar region using the Osseo Transfer System. The patient satisfaction with the surgical procedures was also evaluated. All patients treated with this standardised reconstruction method between 2006 and 2013 at the Department of Cranio-Maxillofacial Surgery, University Hospital Giessen, were included in this study. Complications were recorded and evaluated. Bone graft success and patient satisfaction were documented with a questionnaire, and then confirmed by clinical and radiological follow-up examinations. Fifty-four patients were treated and 64 harvested cylindrical autologous bone grafts were transplanted. In all cases, dental implants could be inserted after bone healing. One patient lost an implant, associated with failure of the bone graft. Six patients who were examined continued to show neurological disorders in locally limited areas. No complete or long-term damage of the inferior alveolar nerve occurred. More than 94% (n = 52) of the patients were 'very satisfied' or 'satisfied' with the results and would recommend this surgical treatment to other patients. The standardised Osseo Transfer was an effective treatment option for small and mid-sized alveolar ridge augmentations. A low donor-site morbidity rate and a high transplant success rate were verified. The Osseo Transfer System demonstrated to be a reliable surgical technique without major complications. We highly recommend this surgical augmentation procedure as a surgical treatment for local bone defects.

Erstpublikation in

Materials 12, 22 (2019-11-19), 3802

URI der Erstpublikation
https://doi.org/10.3390/ma12223802
Sammlungen
  • Publikationen im Open Access gefördert durch die UB
Attribution 4.0 International
Attribution 4.0 International

Kontakt | Impressum | Datenschutzerklärung | OAI-PMH
 

 

Stöbern

Gesamter BestandBereiche & SammlungenOrganisationseinheitDDC-KlassifikationPublikationstypAutorErscheinungsjahrDiese SammlungOrganisationseinheitDDC-KlassifikationPublikationstypAutorErscheinungsjahr

Mein Benutzerkonto

EinloggenRegistrieren

Statistik

Benutzungsstatistik

Kontakt | Impressum | Datenschutzerklärung | OAI-PMH